PNOZ X7 Operating Manual PNOZ X7 19692-EN-05 9 Function Description The safety relay PNOZ X7 provides a safety-oriented interruption of a safety circuit. When the supply voltage is applied via the E-STOP pushbutton, the "POWER" LED is lit. The unit is ready for operation when the start circuit and feedback loop Y1-Y2 is closed. PNOZ X2 Operating Manual PNOZ X2 1003353-EN-05 5 INFORMATION This gives advice on applications and provides information on special fea-tures. Safety Intended use The safety relay PNOZ X2 provides a safety-related interruption of a safety circuit. The safety relay meets the requirements of EN 60947-5-1, EN 60204-1 and VDE 0113-1 Farnell | Electronic Component Distributors
Auxiliary contacts (N/C): 1 Category of output contacts in accordance with EN 954-1 Safety contacts (S) instantaneous: 2 Utilisation category in accordance with EN 60947-4-1 Safety contacts: AC1 at 240 V Imin: 0.01 A, Imax: 8.0 A Pmax: 2000 VA Safety contacts: DC1 at 24 V Imin: 0.01 A, Imax: 8.0 A Pmax: 200 W Auxiliary contacts: AC1 at 240 V
Give our team a call today on. +1 877-830-2021. product type Safety Relay. series PNOZ X2.1. supply voltage 24 V ac/dc. number of channels 1. function E-STOP Monitoring.
Info over eberspacher x2 manual. Resultaten van 8 zoekmachines! Up to PL e of EN ISO 13849-1 PNOZ X2.8P NSG-D-2-332-2009-09 Number of output contacts Safety contacts (S) instantaneous: 3 Auxiliary contacts (N/C): 1 Utilisation category in accordance with EN 60947-4-1 Safety contacts: AC1 at 240 V Imin: 0.01 A, Imax: 6.0 A Order no.: 777302, 787302
Gebruikershandleiding - Windows 10. 2.97 MB. Gebruikershandleiding met kennisgevingen over voorschriften, veiligheid en milieu. 1.67 MB. Gebruikershandleiding - Windows 7. 3.73 MB. Adobe Acrobat Reader is vereist om PDF-gebruikershandleidingen te bekijken en af te drukken. Opmerking: gebruik de meest recente versie van de reader om deze PDF
1 hulpcontact (V) Contactafzekering 10 A snel of 6 A traag volgens EN 60947-5-1, 10/91 Halfgeleideruitgangen 24 V DC/20 mA, kortsluitvast externe voedingsspanning 24 V DC ± 20 % Tijden Opkomvertraging Bewaakte start: max. 100 ms Auto./Handm. start: max. 0,3 s Afvalvertraging Bij noodstop: max. 80 ms Bij uitvallen netspanning: max. 1 s
2VA/24DC. 2W. Alternate Part Number: 774306. Is Pilz PNOZ-X2.1-2S not the part you are wanting? Check out the rest of our store to see what else we have to offer! 4D Controls is proudly owned and operated by a team of Automation and Electrical Engineers. Since 2005, we have been supplying the industries of the world with new, used and surplus
#safetyrelay #relay #safety #PILZ #pnozhow to wire a safety relaypilz pnoz X2 X3 X4Siemens TIA PORTAL Tutorials for Beginnersyoutube.com/playlist
PNOZ XV3.1 Operating Manual PNOZ XV3.1 20515-EN-08 | 5 INFORMATION This gives advice on applications and provides information on special fea-tures. Safety Intended use The safety relay PNOZ XV3.1 provides a safety-related interruption of a safety circuit. The safety relay meets the requirements of EN 60947-5-1 and EN 60204-1 and may be